ANSI NSPI 5 2003 PDF

ANSINSPIResidential Inground Swimming Pools-This standard is a revision of ANSI/NSPI-5 , Standard for Residential Inground Swimming. Standards such as ANSI/AHAM RAC, Room Air For homes with inground pools, ANSI/NSPI , Residential Inground Swimming. For the design, equipment, and installation of residential inground swimming pools. This standard is referenced in the International Codes. PURCHASE .

Author: Malanris Mulabar
Country: Albania
Language: English (Spanish)
Genre: Technology
Published (Last): 27 March 2008
Pages: 30
PDF File Size: 1.37 Mb
ePub File Size: 14.43 Mb
ISBN: 335-3-73037-289-2
Downloads: 82910
Price: Free* [*Free Regsitration Required]
Uploader: Fenrijas

Any private swimming pool that is totally contained within a private structure and surrounded on all four 4 sides by walls of said structure. Suction outlets shall be designed to produce circulation throughout the pool or spa. Need more than one copy? The effective date is October 1, There shall be no physical connection between the water supply line and the pool system.

Minimum water depths and distances for diving hoppers for pools, based on board height above water, shall comply with table A for public pools and table B for private pools in section of this chapter. For the purpose of this section, the front line of any residence shall be a line drawn parallel to any road abutting the lot which intersects the point of the residence located closest to that road.

The alarm shall automatically reset under all conditions. See definition of Private Swimming Pool. This definition includes inground, aboveground and onground swimming pools, wnsi tubs and spas.

The alarm system shall be equipped with a manual means, such as touchpad or switch, to temporarily deactivate the alarm for a single opening. Equipment shall be provided for the disinfection of all pool water. Recirculating systems shall contain rapid pressure filters. The provision of this chapter shall control the design of barriers for residential swimming pools, 20003 and hot tubs.

Spacing between vertical members shall not exceed 1. Already Subscribed to this document.

If the makeup water is added directly to the pool, the outlet shall be at least six inches 6″ above the upper rim of the pool. Any swimming pool other than a private swimming pool. A pool cover which is placed over the water area, and is opened and closed with a motorized mechanism activated by a control switch.

The objective of this standard is to provide recommended minimum guidelines for suction entrapment avoidance in the design, equipment, operation and installation of new and existing swimming pools, wading pools, spas, hot tubs and catch basins for builders, installers, pool operators and service professionals Maximum water velocity limits are: No swimming pool shall extend two feet six inches 2’6″ or more aboveground.

  LYMNOLOGYTEMPLE PONDS PDF

ANSI/NSPI-5 Standard for Residential Inground Swimming Pools (PDF Download)

Maximum system flow is not defined in this 55 the flow requirement is that the equipment shall be sized to provide a turnover of the pool water at least once every twelve 12 hours. Barriers shall be located so as to prohibit permanent structures, equipment or similar objects from being used to climb the barriers.

If a hose connection from a sill cock or other plumbing fixture is to be used for supplying makeup water, then an approved vacuum breaker shall be installed between the sill cock or control valve at the fixture and the hose connection. A receptacle for water or an artificial pool of water intended for the purpose of immersion or partial immersion therein of human beings having a depth at any point of more than two feet aneiplaced in xnsi excavation.

ANSI/APSP Standards & Specifications List

Prior to the construction, installation, enlargement or alteration of any swimming pool or appurtenances, jspi permit shall be obtained from the building officer. The swimming pools’ circulation systems shall consist of pumping equipment, hair and lint catcher, filters, together with the necessary pipe connections to the pool inlets and outlets, facilities and pipe connections necessary for backwashing filter, and filters, and facilities and equipment for disinfecting the pool water.

All discharged water shall be drained entirely upon the property on which the swimming pool is located and shall not flow on any adjoining property.

Conclusions of Law The Florida Building Commission has the specific statutory authority to interpret the provisions of the Florida Building Code by entering a declaratory statement. Your Alert Profile lists the documents that will be monitored. Steps and ladders shall have a handrail on both sides. Jet inlet fittings shall not be deemed subject to this requirement.

Pedestrian access gates shall open outward away from the pool and shall be self-closing and have a self-latching device. All appurtenant structures, installations and equipment, ans as showers, dressing rooms, equipment houses or other buildings and structures, including plumbing, heating and ns;i conditioning systems, shall comply nasi all applicable requirements of this code.

The Petitioner asks three questions regarding this project:. As the voice of the U. The Petitioner is in the process of designing a 10, gallon residential swimming pool with a therapy spa in Bradenton, Florida, in accordance with the Florida Building Code.

The filter backwashing facilities shall asi sufficient to backwash at a rate of twelve 12 gallons per minute per square foot of filter area. Single or multiple pump circulation systems shall be provided with a minimum of two 2 suction outlets of the approved type.

  ENGINEERING ETHICS CHARLES FLEDDERMANN PDF

Pools shall be equipped with facilities for completely nasi the pool and the discharge of the pool water shall be at a rate not exceeding two hundred gallons per minute. Go to new ordinance. All metal fences, enclosures or railings near or adjacent to swimming pools, which might become electrically alive as a result of contact with broken overhead conductors or from any other cause, shall be effectively grounded.

The recirculation system pump shall have sufficient capacity to discharge the volume of water required for an eight 8 hour turnover of the pool against the maximum head in the recirculating system. All walls surrounding an indoor swimming pool shall comply with section AG Access gates shall comply with the requirements of section AG Standards Subsctiption may be the perfect solution.

No current carrying electrical conductors shall cross private residential swimming pools, either overhead or underground or within fifteen feet 15′ of such annsi. No part of any swimming pool shall be located between the front line of any residence located on the same lot as the pool and any street abutting said lot. The building officer may, in his discretion, from time to time, inspect any swimming pools to determine whether or not all applicable provisions of this code regarding health, sanitation and safety are being complied with.

The barrier shall be designed, to the extent reasonably possible, in such a way so as to discourage easy climbing from the outside. Solid barriers which do not have openings, such as a masonry or stone wall, shall not contain indentations or protrusions except for normal construction tolerances and tooled masonry joints. In swimming pools thirty feet 30′ in width or less, water circulation system outlets shall be located so as to provide at least one anai at the deepest point in the pool.

Underwater lighting fixtures shall be approved for the service. For public pools where water skimmers are used, there shall be at least one skimming device for each six hundred square feet